USES
CHEM-CRETE FLEX CCC900 can be use to waterproof concrete, concrete masonry unit blocks and bricks, and cement-rendering. It protects concrete against the effects of free-thaw cycles, de-icing salt, carbon dioxide, acid gases, dilute acids and alkalis. Areas of application include but not limited to:
- Waterproofing of water tanks.
- Sealing internal basement and cellar walls against dampness.
- Protection of concrete structures in marine environments
- Coating of sewage and water channels.
PACKAGING
Product |
Packaging |
CHEM-CRETE FLEX CCC900 |
66.67 Lb (30.24 kg) Unit |
One unit of CHEM-CRETE FLEX CCC900 consists of the following:
Part A (Powder) |
50 Lb (22.68 Kg) Bag |
Part B (Liquid) |
16.67 Lb (7.56 Kg) Pail |
CHEM-CRETE FLEX CCC900 is available in the flowing color combinations:
FINISHED COLOR |
PART A |
PART B |
Light Grey |
Grey Powder |
White Liquid |
White |
White Powder |
White Liquid |
Standard Blue |
Grey Powder |
Blue Liquid |
Standard Green |
Grey Powder |
Green Liquid |
Light Blue |
White Powder |
Blue Liquid |
Light Green |
White Powder |
Green Liquid |
TECHNICAL
Property |
Value @ 77F (25°C) |
Standard |
Mixed Density, Lb/Gal (kg/L) |
15.4 (1.85) |
ASTM D1475 |
Pot Life, minute |
> 240 |
– |
Initial Setting Time, hours |
> 6 |
ASTM C191 |
Final Setting Time, hours |
> 6 |
ASTM C191 |
Adhesion to Concrete,
Psi (MPa), 7 days |
191.45 (1.32)
Concrete Failure |
ASTM D4541
Method A |
Water Permeability, perm |
3.07 * |
ASTM E96 |
Salt Spray Resistance |
300 hours = no effect |
ASTM B117 |
Elongation |
18% |
ASTM D522 |
VOC, grams/Liter |
0 |
– |
Resistance to water pressure |
|
At 1 mm coating thickness |
1 bar no Leakage |
DIN 1048 |
At 2 mm coating thickness |
3 bars no leakage |
DIN 1048 |
* Test performed at two coats of 80 mils (2 mm) thickness.
Recommended Water Pressure’s Application Rates:
Pressure |
Coverage Rate |
14.5 psi (1 bar) |
41 Lb / 100 ft² (2 kg/m²) |
43.5 psi (3 bar) |
82 Lb / 100 ft² (4 kg/m²) |
101.5 psi (7 bar) |
123 Lb / 100 ft² (6 kg/m²) |
Coverage: 0.36 Lb/ft2 (1.76 kg/m2) for 40 mil (1 mm) thickness coating. To insure total protection, two coats are recommended. Using this coverage rate, one unit of CHEM-CRETE FLEX CCC900 will cover up to 185 ft2 (17.18 m2). Variation in coverage rate might occur depending on the application uniformity and the substrate porosity.
Chemical Resistance: Good chemical resistance to gasoline, diesel oil, sodium hydroxide, calcium chloride and sewage. Coated surfaces exhibit good resistance to mild acids.
APPLICATION
Surface Preparation: The areas to be treated must be free from all grease, oil, dust, residual curing compound, mold release agent or other contaminants that could impair adhesion. Smooth surfaces should be roughened. All loose material and surface laitance should be removed by shot blasting or hydro jetting. Mechanical wire brushing may be appropriate for small areas. Spalled concrete should be cut back to sound concrete and leveled with suitable cementitious repair mortar such as CEM220. Conventional concrete curing compounds should be removed before application of CHEM-CRETE FLEX CCC900. CHEM-CRTE CEM241 can be used to seal any existing pin holes.
Mixing: CHEM-CRETE FLEX CCC900 is supplied in pre-measured units and should be mixed on site utilizing clean containers. Slowly add the powder to the liquid and mix using slow speed drill fitted with suitable paddle. The workability can be increased by addition of small amounts of clean water at maximum of 12 FL oz (355 milliliters) per 67.67 Unit of CHEM-CRETE FLEX CCC900.
Placing: CHEM-CRETE FLEX CCC900 is best applied using spray techniques. A stiff bristle brush or roller may be employed and trowel application can be undertaken as necessary. Apply the first coat approximately 40 mil (1 mm) thick onto the prepared substrate. To ensure total protection, a second coat should be applied in the same way after waiting 30 minutes depending on the temperature (when the first coat is stable but not fully set).
Cleaning: all tools should be cleaned with water immediately after use.
STORAGE
Store in dry frost-free conditions at moderate temperatures no greater than 95ºF (35ºC). Protect the liquid Part B from freezing.
SAFETY
As with all chemical products, care should be taken during use and storage to avoid contact with eye, mouth, skin, and foodstuffs. Treat splashes to eye and skin immediately. If accidentally ingested seek immediate medical attention.
WARRANTY
LIMITED WARRANTY: International Chem-Crete Inc. warrants that, at the time and place we make shipment, our materials will be of good quality and will conform to our published specifications in force on the date of acceptance of the order.
DISCLAIMER: The information contained herein is included for illustrative purposes only and, to the best of our knowledge, is accurate and reliable. International Chem-Crete Inc. is not under any circumstances liable to connection with the use of information. As International Chem-Crete Inc. has no control over the use to which others may put its products, it is recommended that the products be tested to determine the suitability for specific applications and/or our information is valid in particular circumstances. Responsibility remains with the architect or engineer, contractor and owner of the design, application and proper installation of each product. Specifier and user shall determine the suitability of the product for specific application and assume all responsibility in connection therewith. AM180319.